Every electric hot water system needs its own dedicated circuit sized to the unit's power draw, it can't share a circuit with anything else. Wiring a standard storage system typically costs $200 to $400, while a continuous flow electric unit can cost $500 to $1,200 or more because of its much higher load.
Does a Hot Water System Need Its Own Circuit?
Yes. Under the wiring rules, an electric hot water system must be supplied by a dedicated circuit run directly from the switchboard, sized specifically to that unit. It can't be wired to share a circuit with power points or other fixed appliances.
Storage vs Continuous Flow: Why the Electrical Load Is So Different
A standard electric storage hot water system heats a tank gradually and draws a relatively modest, steady load, typically wired on a circuit similar in size to other major appliances. A continuous flow (instantaneous) electric unit heats water on demand, which means a very high power draw for the short time it's running, often several times higher than a storage unit. That difference is the main reason continuous flow electric systems cost significantly more to wire.
Switchboard Capacity Checks
Because continuous flow electric units draw such a high load, older switchboards often don't have the spare capacity to add one without an upgrade first. This is worth checking before committing to a continuous flow electric system over a storage or gas option, since the switchboard upgrade can add significantly to the total cost.
What the Electrical Work Actually Involves
- A dedicated circuit and breaker sized to the specific unit's rated load.
- Correct cable sizing based on the unit's current draw and the length of the run from the switchboard.
- An isolating switch near the unit so it can be safely isolated for servicing.
- Switchboard capacity confirmation, with an upgrade quoted separately if needed.
What Pushes the Price Up
A switchboard upgrade needed to support a continuous flow unit is the single biggest cost driver. Longer cable runs between the switchboard and the hot water system's location, and installations in hard-to-access areas, also add to the total.
Key Takeaways
- Electric hot water systems always need a dedicated circuit, never a shared one.
- Storage systems draw a moderate, steady load; continuous flow electric units draw a very high load only while heating.
- Continuous flow electric systems often require a switchboard upgrade to supply enough capacity.
- The circuit breaker and cable are sized to the specific unit's rating, not a generic standard size.
- Plumbing and electrical work are usually coordinated between a plumber and an electrician.